- Specifications
- Documents
- Description
- Heat Pump Outdoor Unit
- Type Single Zone, Hyper Heat
- Voltage Rating 208/230 Volt AC
- Current Rating 0.5 Amp (Motor)
- Frequency Rating 60 Hertz
- Number of Phases 1
- Power Rating 890 Watt Cooling, 900 Watt Heating
- Cooling Capacity 12000 BTU/HR
- Temperature Control Type Thermostat
- Connection Type Terminal Block
- Operating Temperature 115 Deg F Dry (Cooling), 75 Deg F Dry (Heating)
- Enclosure Finish Munsell 3Y 7.8/1.1
- Size 31-1/2" Width x 11-1/4" Depth x 21-5/8" Height
- Weight 83 Lb
- Approval ETL (Canada and US)
- Refrigerant Type R410A
- Compressor Type Driven Twin Rotary DC Inverter
- Heating Capacity 13000 BTU/HR
- Airflow Rating 1215/1201 CFM
- Energy Efficiency Ratio 25.5 SEER, 12 HSPF
- Minimum Circuit Ampacity 9 Amp
- Refrigerant Pipe Size 1/4" Liquid, 3/8" Gas
- Sound Level 48 dB
- Applicable Standard AHRI
- Warranty 5 Year Limited (Parts), 7 Year Limited (Compressor)
5 Year Limited (Parts), 7 Year Limited (Compressor) Warranty. Energy Star Rated