- Specifications
- Documents
- Description
- Burner Control
- Flame Establishing Period 15 Second (Pre-Time), 30 Second (Post-Time)
- Pilot Type Intermittent, Interrupted
- Voltage Rating 102 to 132 Volt AC at 60 Hertz
- Operating Temperature -40 to 150 Deg F
- Application Boiler, Furnace and Water Heater
- Approval UL 372, UL 1998, CSA B140
- Lockout Time 15 Second
- Current Rating 100 Milliamp (Plus Burner Motor/Ignitor/Valve Loads)
- Motor Rating 120 Volt AC, Motor FLA 10 Amp, Motor LRA 60 Amp
- Ignitor Rating 120 Volt AC, 3 Amp at 0.7 PF Minute
- Solenoid Valve Rating 120 Volt AC, 1 Amp at 0.7 PF Minute
- Thermostat Anticipator Current Rating 0.1 Amp
- Thermostat Voltage Rating 24 Volt AC
- Warranty 5 Year
The Beckett Genesis Advanced Burner Control is a 120 Volt Ac Primary Safety Control for Residential and Light Commercial Oil Burners Used in Boiler, Furnace, and Water Heater Applications; The Genesis is Used with a Suitable Cad Cell Flame Sensor to Control the Oil Burner Motor, Ignitor and Optional Solenoid Valve; It has 24 Volt Ac Thermostat Inputs Compatible with Both On/Off and Power Stealing Thermostats; It can Provide Interrupted or Intermittent Duty Ignition, and has a 15-Second Lockout Time; Thermostat and Boiler Control Compatible; Programmable Valve-On Delay and Motor-Off Delay; Three Indicator Lights for System Monitoring and Diagnostics; Two Communication Ports for Adding Alarm Contacts, Programming Display, And/or Future Wireless Communications; Welded Relay Protection with Redundant Motor Relays; Limited Reset and Limited Recycle; Sleek, Modern Design; Technician Pump Prime Mode; 18 Months Warranty