- Specifications
- Description
- Gas Power Burner Control
- Flame Establishing Period 4 Second (Lock Out)
- Voltage Rating 120 Volt AC 50/60 Hertz (Igniter/Motor), 24 Volt AC 50/60 Hertz (Control/Gas Valve/Air Proving Switch)
- Operating Temperature -40 to 175 Deg F
- Application Residential and Light Commercial Gas Heating
- Approval UL (Canada and US), CSA C22.2
- Current Drawn 0.2 Amp
- Output Rating 2 Amp (24 Volt Main Valve), 7.4 Amp (120 Volt Motor Relay), 1.0 Amp (120 Volt Igniter Relay)
- Timing 1 to 240 Second (Pre-Purge), 90 to 300 Second (Inter-Purge)
- Additional Ratings 1 Microamp (Minimum Flame Current), 0.8 Second (Flame Failure Response Time), 24 Volt AC (Thermostat Voltage)
- Moisture 5 to 95 Percent RH (Non Condensing)
- Applicable Standard ANSI Z21.20
3 LEDs Provide Basic Diagnostic Information; Single or Multiple Trials for Ignition before Lockout; Selectable Relight or Recycle Operation on Loss of Flame; The Microprocessor is Checked for Proper Operation before Each Cycle; Gas Valve Relay Check on Each Cycle; Communication Port Link New Alarm Module and Future Products