48245S Carlin Primary Control 45-TFI With Smart Ignition

CAR48245S MFG #: 48245S
  • Manufacturer Name: Carlin
  • Specifications
  • Documents
  • Description
  • Boiler Cad Cell Oil Primary Control
  • Type Furnace/Wall Mount
  • Flame Establishing Period 45 Second
  • Pilot Type Intermittent, Interrupted
  • Voltage Rating 120 Volt AC at 60 Hertz
  • Operating Temperature 32 to 140 Deg F
  • Application Residential/Commercial Boiler Oil Burner
  • Approval UL (Canada and US)
  • Storage Temperature -40 to 185 Deg F
  • CAD Cell Resistance 1500 Ohms
  • Thermostat Anticipator Current Rating 0.1 Amp
  • Motor Load 10 FLA/60 LRA
  • Ignitor Load 120 Volt AC at 60 Hertz
Oil Pump BLEED Assist 60 Seconds; Recycle on Flame Failure; Diagnostic LED's Status, Lockout, Flame; In creased Flame Accuracy; Thermostat/Aquastat Compatible; Improved SMC Technology; Works Well with Generators; In termittent Duty when You Need it, Ignitor Saving Interrupted Duty when You Don't; Smart Ignition