260 1 STAGE BOILER & DHW CONTROL

TEK260 MFG #: 260
  • Manufacturer Name: Tekmar
  • Specifications
  • Documents
  • Description
  • Boiler Control
  • Item Boiler Control
  • Type Probe
  • Applicable Standard UL 873, CSA C22.2, CSA (Canada and US)
  • Actuation Type Automatic
  • Switch Type DIP
  • Overall Dimensions 7-9/16" Width x 2-13/16" Depth x 6-5/8" Height
  • Input Supply Rating 1300 VA at 120 Volt AC 50/60 Hertz
  • Inclusions/Features (1) Outdoor Sensor, (1) Universal Sensor, DHW
  • Application Baseboard, Mixed Radiant Heating System, Combination Space Heating, Domestic Hot Water Heating Installation
  • Enclosure A, Blue PVC Plastic
  • Optional Device Type 032/076/077
  • Relay Rating 240 Volt AC, 10 Amp, 1/3 HP
  • Warranty 3 Year Limited
Designed to Operate a Single Boiler Using Outdoor Temperature Reset; This Control Regulates a Single Heating Water Temperature Through Outdoor Temperature Reset and Domestic Hot Water Control; It is Capable of Controlling a Single On/Off Boiler and can Receive Both Space Heating and Dhw Heat Demands; Operate Hydronic Heating Equipment with Outdoor Temperature Reset to Gain Energy Savings and Indoor Comfort; Setback Input for Energy Saving; Warm Weather Shut Down; Automatic Boiler Differential; Quick Setup for Easy Installation and Programming; User Comfort Adjustment to Increase or Decrease Building Space Temperature; Advanced Settings to Fine-Tune Building Requirements; Test Sequence to Ensure Proper Boiler Operation; Pump and Valve Exercising; Powered Boiler Pump Output; Dhw Pump or Valve Operation; Dhw (Domestic Hot Water) has Priority Over Space Heating; 3 Year Limited Warranty